Experience the Next Generation of Immersion Cooling Technology
Transform your data center and mining operations with MARA 2PIC1000, a two-phase immersion cooling system.
Leveraging advanced technology, the MARA 2PIC1000 delivers exceptional performance, efficiency, and space savings, ensuring your operations stay cool, even under the most extreme conditions.
2PIC1000 TANK
2PIC BY MARA
Setting a New Standard for Data Centers
Features for transforming your computing environment
Compact and Modular
Reduces data center space requirements up to 75%.
Extreme Power Density
2-4X more power within the same space.*
Energy Efficient
Up to 60% reduction in cooling overhead.*
Remote Management
Built for unmanned operations, spend less time on maintenance.
Unprecedented Overclocking
Enables 60% to 100% overclocking for ASIC miners.
Cross-Climate Use
Operate seamlessly in any environment from -20°C to 50°C ambient temperature.
Reliable Fluid
<5% annual loss, safe and low environmental impact.
Heat Capture Ready
Efficient high-temperature water output for heating applications.
*When compared to traditional air-cooled and single-phase immersion setups
Model Specification
MODEL
MARA 2PIC1000
FLOOR AREA
8’ x 4‘ x 4'
COOLING PERFORMANCE
500 kW @ 40°C ambient 670 kW @ 35°C
COOLING OVERHEAD
60% less than single-phase immersion
OVERCLOCK POTENTIAL
Up to 100%
ENVIRONMENTAL PROTECTION
Hurricane Resistant
Mining Calculator
Maximize Your Mining Efficiency with Precision Overclocking Insights
Hardware
Overclock your Bitmain Antminers and Auradine Teraflux™ miners with minimal impact on joules per terahash efficiency.
BITMAIN ANTMINER
AURADINE TERAFLUX™
2PIC Under the Hood
MORE COOLING
MORE POWER
MORE BITCOIN
Frequently Asked Questions
Everything you need to know about 2PIC.
What is two-phase immersion cooling (2PIC)?
2PIC is the next generation of immersion cooling technology. These systems consist of a sealed-off tank where computing devices are submerged in a pool of dielectric fluid. As the devices heat up, the fluid boils into gas, which then rises, cools, and condenses back into liquid. The cooled liquid then returns to the bottom of the container, where it can absorb more heat.
How does 2PIC benefit Bitcoin mining operations?
MARA’s 2PIC system sets a new standard for data centers, significantly benefiting Bitcoin mining operations by providing a compact and modular design that slashes data center space requirements. It provides exceptional power density, allowing for more power within the same area. The system boosts performance and enables substantial overclocking of ASIC miners. The 2PIC system is heat capture ready and uses high-temperature water for heat exchange. Moreover, the 2PIC system also achieves a higher energy efficiency than air-cooled or single-phase immersions systems, requiring 80% less energy for cooling overhead. Additionally, the system supports remote management for streamlined, low-maintenance operations.
What differentiates MARA 2PIC from alternative two-phase immersion cooling solutions?
While other companies have launched two-phase immersion cooling systems in the past, our 2PIC system contains several new patent-pending innovations. We use a fluid with a higher boiling point, which provides a more effective cooling solution. This design, coupled with our fluid of choice, enables ASIC miners to be overclocked to significantly higher hash rates. For example, XP miners can be overclocked by 100% and up to 50% with minimal change in J/TH. Alternatively, it allows Auradine miners to be packed more densely into the 2PIC system, generating a higher hash rate in a small form factor.
Why should you choose 2PIC despite its perceived complexity and potential cost implications?
While advanced, our 2PIC system is a sound choice. The technological complexity is designed to surpass single-phase immersion, hydro, and air-cooled systems in power density, efficiency, and operational autonomy. Our 2PIC solution has been meticulously engineered with redundancies to ensure reliability without significantly increasing costs. For instance, our system includes four power distribution units (PDUs), yet only three are necessary to power the miners – this is just one example of the built-in safeguards. Thanks to MARA's innovative efforts, we believe our solution offers you a better cost per megawatt, return on investment, and total cost of ownership when compared against other forms of cooling technologies.
What is the pricing structure for the 2PIC system?
The cost of MARA 2PIC is competitive with single-phase immersion systems. For detailed pricing, tailored to your specific Bitcoin mining needs and site requirements, we invite you to consult with our sales team. They are ready to provide you with a personalized quote and assist you in evaluating the best solutions for your setup. You can contact them directly at 2pic@mara.com for a consultation and a customized pricing structure.